Economy 2 zone microprocessor panel code entry (does not extend)
Note: Maximum battery size & type:- 2 x 12v 3.3Ahr. Valve Regulated Lead Acid connected in series.

Fully compliant with EN54 parts 2 and 4
• Available in 2, 4 and 8 zone standard and economy versions
• Installer-friendly design accommodates easy first fix and straightforward
maintenance
• Attractive flush or surface mountable plastic lid and enclosure
• Auxiliary remote, aux. fire, fault & reset outputs
• ‘Class change’ and Alert inputs
• Four conventional sounder circuits
• Low quiescent current - for extended standby times with small batteries
• Wide range of Access Level 2 user functions allow a large number of features to
be disabled and/or enable in line with EN54.
• Wide range of access level 3 engineering functions including:-
• Zone test mode (standard and economy panels)
• Programming of coincidence on zones (standard panel only)
• Selectable zone delay facility (standard panel only)
• Non-latching zones facility (standard panel only)
• Multiple indicators provide comprehensive overview of system status
• End of line units included (one per zone)
• Push button access code entry to Access Levels 2 and 3
• Integral 1.5A switch mode PSU designed for a wide range of input voltage
including 110V and 240V (If 110V version is required please specify when
ordering)
• Detector and sounder circuits share common negative allowing three wire retroinstallation
• System can be expanded to include up to eight two-wire repeaters with full Access
Level 2 control (one FP761 Network Communication Card required
per Repeater system) Available on Standard panels only.

Specification

Model:                                              702, 704, 708
Mains supply voltage:                         230V a.c. ±10% 50/60 Hz
Total output current limited to:             1.54A @ 230V a.c.
Number of detector zones:                       2 4 8           
Max. smoke/heat detectors:                    25 25 25
Number of sounder circuits:                      4 4 4
Max. bells:                                          32@25mA                                     

Max. sounders @ 10mA:                        40@20A
Sounder outputs fused at:                     800mA
Quiescent current (mA):                        100mA
Physical dimensions (W x H x D):           380 x 235 x 96mm
Weight (without batteries):                     1.75kg